- Manuals
- Brands
- York Manuals
- Chiller
- YCAS Series
- Wiring diagram
Air-cooled screw liquid chillers
Hide thumbs Also See for YCAS Series:
- (216 pages) ,
- (168 pages)
-
- Contents
- Table of Contents
- Bookmarks
Table of Contents
-
Table of Contents
-
Nomenclature
-
Electrical Notes
-
Electrical Data
-
Wiring Diagram
-
Fig. 1 - Wiring Diagram - Across-The-Line Start
-
Fig. 2 - Wiring Diagram - Across-The-Line Start
-
Elementary Diagram
-
Fig. 3 - Elementary Diagram - Across-The-Line Start
-
Wiring Diagram
-
Fig. 4 - Wiring Diagram - Wye-Delta Start
-
Fig. 5 - Elementary Diagram - Wye-Delta Start
-
Elementary Diagram
-
Fig. 6 - Elementary Diagram - Wye-Delta Start
-
Power Panel
-
Fig. 7 - Power Panel (System #1) Component Locations
-
Control Panel
-
Fig. 8 - Control Panel Component Location
-
Power Panel
-
Fig. 9 - Power Panel (System #2) Component Locations
-
Connection Diagram (System Wiring)
-
Fig. 10 - Connection Diagram (System Wiring)
-
Compressor Terminal Box
-
Fig. 11 - Compressor Terminal Box
-
Elementary Diagram Starter Control Circuit
-
Fig. 12 - Elementary Diagram Starter Control Circuit
-
Elementary Diagram Fan Control
-
Fig. 13 - Elementary Diagram Fan Control Circuit
Advertisem*nt
Quick Links
- 1 Nomenclature
- Download this manual
AIR-COOLED SCREW LIQUID CHILLERS
WIRING DIAGRAM
New Release
Form 201.19-W3 (1104)
YCAS AIR-COOLED LIQUID CHILLERS
YCAS0373 THROUGH YCAS0653
STYLE G (R22)
(50 Hz)
Table ofContents
Advertisem*nt
Table of Contents
Related Manuals for York YCAS Series
-
Air-cooled screw liquid chillers (216 pages)
-
Air-cooled screw liquid chillers (168 pages)
-
Chiller York MILLENNIUM YCAS0130 User Manual
Air cooled screw liquid chillers (style f) (28 pages)
-
Ycas air-cooled liquid chillers style g (204 pages)
-
Chiller York YCAS0130EC Manual
Air-cooled screw liquid chillers (32 pages)
-
Chiller York MILLENNIUM YCAS0250 Wiring Diagram
Air cooled screw liquid chillers style f (34 pages)
-
Chiller York eco YCAS Series Manual
Optimized r-407c air-cooled liquid chiller (232 pages)
-
Air-cooled screw liquid chillers (156 pages)
-
Chiller York YCAS0685EB Wiring Diagram
Air cooled screw liquid chillers (32 pages)
-
Air-cooled screw liquid chiller (152 pages)
-
Air cooled screw liquid chillers air cooled screw hermetic (124 pages)
-
Air-cooled screw liquid chillers (192 pages)
-
Chiller York YCAS0693 Wiring Diagram
Air-cooled liquid chillers, 3 /4 compressor/r22, style g, 50 hz (48 pages)
-
Chiller York MILLENNIUM YCAS 250 Manual
Air cooled liquid chiller (196 pages)
-
Chiller York YCAS0685 Manual
Ycas air-cooled liquid chillers (48 pages)
-
Air-cooled liquid chillers (216 pages)
Summary of Contents for York YCAS Series
- Page 1 AIR-COOLED SCREW LIQUID CHILLERS WIRING DIAGRAM New Release Form 201.19-W3 (1104) YCAS AIR-COOLED LIQUID CHILLERS YCAS0373 THROUGH YCAS0653 STYLE G (R22) (50 Hz)
-
Page 2: Table Of Contents
FIG. 10 – CONNECTION DIAGRAM (SYSTEM WIRING)............27 FIG. 11 – COMPRESSOR TERMINAL BOX ................28 FIG. 12 – ELEMENTARY DIAGRAM STARTER CONTROL CIRCUIT ........29 FIG. 13 – ELEMENTARY DIAGRAM FAN CONTROL CIRCUIT ..........30 YORK INTERNATIONAL YORK INTERNATIONAL... -
Page 3: Nomenclature
FORM 201.19-W3 (1104) NOMENCLATURE The Model Number denotes the following characteristics of the unit: 0373 YORK Chiller Design Series YC = YORK Chiller Type Start Y = Star (WYE)-Delta Air-Cooled X = Across-the-Line Compressor Type S = Screw Voltage Code... -
Page 4: Electrical Notes
Factory provided circuit breakers in each motor control center. 11. Consult factory for Electrical Data on units equipped with “High Static Fan” option. 50Hz High Static Fans are 3.5kW each. 12. FLA for each “Low Noise Fan” motor: 380v/50Hz = 4.1A. YORK INTERNATIONAL... - Page 5 FORM 201.19-W3 (1104) This page intentionally left blank. YORK INTERNATIONAL...
-
Page 6: Electrical Data
2/0 - 500 # 6 - 350 (2) 3/0-250 17.1 0653 2/0 - 500 # 6 - 350 (2) 3/0-250 17.1 * “Optional” Circuit Breakers are REQUIRED for units with CE mark. See page 4 for Electrical Data Notes. YORK INTERNATIONAL... - Page 7 # 6 - 350 17.1 0573 2/0 - 500 # 6 - 350 (2) 3/0-250 17.1 0623 2/0 - 500 # 6 - 350 (2) 3/0-250 17.1 0653 2/0 - 500 # 6 - 350 (2) 3/0-250 17.1 YORK INTERNATIONAL...
- Page 8 (2) 2/0 - 500 (2) 250-500 0543 (2) 1/0 - 300 (2) 3/0-250 0573 (2) 2/0 - 500 (2) 250-500 0623 (2) 2/0 - 500 (2) 250-500 0653 (2) 2/0 - 500 (2) 250-500 See page 4 for Electrical Data footnotes. YORK INTERNATIONAL...
- Page 9 17.1 107.9 17.1 0403 117.7 17.1 117.7 17.1 0453 139.5 17.1 139.5 17.1 0503 161.3 17.1 161.3 17.1 0543 140.6 17.1 140.6 17.1 0573 167.9 17.1 167.9 17.1 0623 183.1 17.1 183.1 17.1 0653 167.9 17.1 167.9 17.1 YORK INTERNATIONAL...
- Page 10 (2) 3/0-250 0573 (2) 2/0 - 500 (2) 250-500 0623 (2) 2/0 - 500 (2) 250-500 0653 (2) 2/0 - 500 (2) 250-500 Option not available for units with CE mark. See page 4 for Electrical Data footnotes. YORK INTERNATIONAL...
- Page 11 11, 12 11,12 Volts YCAS Y-LRA X-LRA Qty. Y-LRA X-LRA Qty. (Ea.) (Ea.) (Ea.) (Ea.) 17.1 0373 17.1 17.1 0403 17.1 17.1 0453 17.1 17.1 0503 17.1 17.1 0543 17.1 17.1 0573 17.1 17.1 0623 17.1 17.1 0653 17.1 YORK INTERNATIONAL...
- Page 12 1. – – – – – – – Dashed Line indicates Field Provided Wiring. 2. The above recommendations are based on the National Electric Code and using copper connectors only. Field wiring must also comply with local codes. YORK INTERNATIONAL...
- Page 13 FUSE SIZE SWITCH SIZE 115V-1Ø CONTROL POWER SUPPLY (UNITS WITH STANDARD CONTROL CIRCUIT TRANSFORMER) CONTROL RECOMMENDED NON-FUSED NO. OF POWER (MAX LOAD DUAL ELEMENT DISCONNECT COMPRESSORS SUPPLY CURRENT) FUSE SIZE SWITCH SIZE 400V - 50 HZ 6.3A — YORK INTERNATIONAL...
-
Page 14: Wiring Diagram
6. Alarm contacts are for annunciating alarm/unit mal func - (Class 2) Connections. See Note 2 tion. Con tacts are rated at 115V, 100VA, re sis tive load only, Terminal Block for YORK Connections Only and must be suppressed at load by user. Wiring and Components by YORK 7. -
Page 15: Fig. 2 - Wiring Diagram - Across-The-Line Start
FORM 201.19-W3 (1104) WIRING DIAGRAM (CONT'D) ACROSS-THE-LINE START 035 15164 103 REV F SEE DETAIL "C" ON DRAWING 035-15164-102 LD09233 FIG. 2 – WIRING DIAGRAM – ACROSS-THE-LINE START YORK INTERNATIONAL... -
Page 16: Elementary Diagram
FORM 201.19-W3 (1104) ELEMENTARY DIAGRAM LD09480 FIG. 3 – ELEMENTARY DIAGRAM – ACROSS-THE-LINE START YORK INTERNATIONAL... - Page 17 BAS in puts on ter mi nals 13 - 19 or TB3, or any oth er ter mi nals, must be sup- pressed with a YORK P/N 031- 00808-000 sup pres sor across the re lay/con tac tor coil.
-
Page 18: Wiring Diagram
6. Alarm contacts are for annunciating alarm/unit mal func - (Class 2) Connections. See Note 2 tion. Con tacts are rated at 115V, 100VA, re sis tive load only, Terminal Block for YORK Connections Only and must be suppressed at load by user. Wiring and Components by YORK 7. -
Page 19: Fig. 5 - Elementary Diagram - Wye-Delta Start
FORM 201.19-W3 (1104) WIRING DIAGRAM (CONT'D) WYE-DELTA START LD09236 FIG. 5 – ELEMENTARY DIAGRAM – WYE-DELTA START YORK INTERNATIONAL... -
Page 20: Elementary Diagram
FORM 201.19-W3 (1104) ELEMENTARY DIAGRAM LD09480 FIG. 6 – ELEMENTARY DIAGRAM – WYE-DELTA START YORK INTERNATIONAL... - Page 21 BAS inputs on ter mi nals 13 - 19 or TB3, or any oth er ter mi nals, must be sup- pressed with a YORK P/N 031- 00808-000 sup pres sor across the re lay/con tac tor coil.
-
Page 22: Power Panel
FORM 201.19-W3 (1104) POWER PANEL (SYSTEM #1) 035 18672 104 REV E LD09238 FIG. 7 – POWER PANEL (SYSTEM #1) COMPONENT LO CA TIONS YORK INTERNATIONAL... -
Page 23: Control Panel
FORM 201.19-W3 (1104) CONTROL PANEL 035 18672 104 REV E LD010026 FIG. 8 – CONTROL PANEL COMPONENT LOCATION YORK INTERNATIONAL... -
Page 24: Power Panel
FORM 201.19-W3 (1104) POWER PANEL (SYSTEM #2) 035 18672 104 REV E LD09240 FIG. 9 – POWER PANEL (SYSTEM #2) COMPONENT LO CA TIONS YORK INTERNATIONAL... - Page 25 FORM 201.19-W3 (1104) LEGEND LD010027 YORK INTERNATIONAL...
- Page 26 FORM 201.19-W3 (1104) 035 15164 102 REV E LD03282 LD03283 LD03284 YORK INTERNATIONAL...
-
Page 27: Connection Diagram (System Wiring)
FORM 201.19-W3 (1104) CONNECTION DIAGRAM (SYSTEM WIRING) LD09242 FIG. 10 – CONNECTION DIAGRAM (SYSTEM WIRING) YORK INTERNATIONAL... -
Page 28: Compressor Terminal Box
FORM 201.19-W3 (1104) COMPRESSOR TERMINAL BOX 035 18672 105 REV A FIG. 11 – COMPRESSOR TERMINAL BOX LD09243 YORK INTERNATIONAL... -
Page 29: Elementary Diagram Starter Control Circuit
FORM 201.19-W3 (1104) ELEMENTARY DIAGRAM STARTER CONTROL CIRCUIT 035 15164 102 REV E LD010028 FIG. 12 – ELEMENTARY DIAGRAM STARTER CONTROL CIRCUIT YORK INTERNATIONAL... -
Page 30: Elementary Diagram Fan Control
ELEMENTARY DIAGRAM FAN CONTROL 035 15164 102 REV E #3/#4 #3/#4 #5/#6 #5/#6 #7/#8 #3/#4 #5/#6 #7/#8 #9/#10 LD06840 FIG. 13 – ELEMENTARY DIAGRAM FAN CONTROL CIRCUIT... - Page 31 FORM 201.19-W3 (1104) NOTES YORK INTERNATIONAL...
- Page 32 P.O. Box 1592, York, Pennsylvania USA 17405-1592 Tele. 800-861-1001 Subject to change without notice. Printed in USA Copyright © by York International Corporation 2004 www.york.com ALL RIGHTS RESERVED Form 201.19-W3 (1104) New Release...
This manual is also suitable for:
Ycas 0373Ycas 0403Ycas 0453Ycas 0503Ycas 0543Ycas 0573 ... Show all